Bar30 Pressure Sensor

The Bar30 pressure sensor can be relocated to the Surveyor 240 by using the Surveyor's spare penetrator hole.

Hardware Installation

Using a T10 Torx screwdriver, slightly loosen all screws on the back plate of the Surveyor 240 housing. Once all screws have been loosened, remove all of the screws and carefully lift off the back plate.

Locate the four mounting screws securing the Surveyor 240 circuit board. Using a 2.5mm hex screwdriver, remove these screws. Gently lift the Surveyor 240 board straight up and out of the housing.

Using two 16mm wrenches, unscrew the blank penetrator and retaining nut from the housing. Apply grease (e.g., Molykote) to the o-ring on the pressure sensor. Insert the sensor into the port previously occupied by the blank penetrator and hand-tighten the retaining nut. Then, using the 16mm wrenches, securely tighten the pressure sensor and nut to ensure the sensor is firmly seated.

Plug the depth sensor into the port on the Surveyor 240 board labeled Depth Sensor.

With the sensor installed and the board in place, reattach the Surveyor 240 board to the board beneath it, and then to the posts using the four screws. Ensure that the large o-ring is seated in the groove of the main housing, then reinstall the back plate and tighten all screws with the T10 Torx screwdriver in a star pattern until each screw is hand tight.

Reading Sensor Data

Pressure data from the Surveyor240 is transmitted in the WATER_STATS packet. The packet payload contains:

  • pressure: reported in Bar

  • temperature: reported in degrees Celsius

Last updated