Common Parameter | Omniscan 450 FS and SS |
---|---|
Parameter | Omniscan 450 FS | Omniscan 450 SS |
---|---|---|
Note 1: Far Field distance is the range beyond which the beam width specification is valid. At nearer distances the effective beam width gets wider, and sidelobes get larger.
Note 2: This is the nominal theoretical 2-way (transmit and receive) 3dB beam width.
Note 3: SonarView will allow range settings out to 200m. Rather than inflate the range specifications here we use ranges at which we have comfortably identified targets.
Viewing Software
SonarView by Cerulean
Frequency
450 kHz
Range Resolution
Up to 1/1200 of range setting
Maximum Ping Rate
20 pings per second up to 30m range, thereafter limited by range and speed of sound. Examples: 10 pps @ 50m, 5 pps @ 140m range setting
Power Supply
10-30 Volts, 5 watts max at idle, 10 watts max while pinging
Data Interface
100BaseT Ethernet
Electrical Connection
Single cable with 4 pin JST for data (Blue Robotics Ethernet standard), plus a wire pair for power. Adapter provided for standard RJ-45 ethernet connection.
Maximum Range (Note 3)
100m
150m
Far Field (Note 1)
5m
9m
Beam Width (Note 2)
0.8 degrees
0.5 degrees
Beam Height
50 degrees
50 degrees
Maximum Operating Depth
100m and 300m versions
300m
Weight in Air
440g (100m), 825g (300m)
180g (transducer only)
Weight in Water
-60g (100m), +325g (300m)
149g (transducer only)
Overall Dimensions
55x67x200mm
318x30x20mm