> For the complete documentation index, see [llms.txt](https://docs.ceruleansonar.com/c/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.ceruleansonar.com/c/dvl-75/mounting-the-dvl-components/mounting-the-electronics-stack.md).

# Mounting the Electronics Stack

The electronics stack can be mounted in a shared enclosure with other electronics, in a Blue Robotics 3” (or larger) enclosure, or in the optional Cerulean 300m Electronics Enclosure. Orientation of the stack is not important. The electronics dissipate roughly 5 watts of heat (another 3 watts or so goes into the water as acoustic energy), so a cooling path to water is strongly recommended. Mounting in a Cerulean 300m Enclosure or on a Blue Robotics 3” O-ring flange provides sufficient thermal conduction pathway to the water. Running the system out of water for long periods of time (30+ minutes) without some sort of cooling is not recommended.

![The Optional 300m Electronics Enclosure with a bracket for the BlueROV Payload Skid](https://400583030-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FIUx8F0dEX9C01W3iSbva%2Fuploads%2FsjVQN7b7JtyKRDSeUHJf%2Fimage.png?alt=media\&token=f010a1a0-b653-4706-b360-8f2497a9cc27)

![The Optional 300m Electronics Enclosure with a bracket (not supplied) for the BlueROV23 Heavy Thruster Guard](https://400583030-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FIUx8F0dEX9C01W3iSbva%2Fuploads%2F1VvrNbbPwjfbHmUX54CC%2Fimage.png?alt=media\&token=3bfa9b7f-4f43-448e-883a-1fc743cf2efb)